Gold-life micropump development and production center

                        Homepage
                        Favorite

                        | Center introduction| Product Introduction | Applied Communication |  Services  | Contact|

                        Select micro-pump

                        pressure unit conversion table

                        GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        (mA)

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        (mL/min)

                        Weight

                        (g)

                        Pump Size

                        Detailed Structure of the show

                        reference Appearance

                        GminiPA-1

                        3.5

                        30-50

                        35

                        -25

                        800

                        16

                        162431

                        >>here

                        GminiPA-2

                        3.5

                        30-40

                        35

                        -20

                        300

                        16

                        162431

                        >>here

                        Ibid

                        pressure unit conversion table

                        GminiP Series of micro-Pump Low power consumption, current, noise, anti-corrosive gases and ozone gas, and with two mounting holes. Analyzer for Pocket suction pump, gas sampling, medical instrument, beauty instrument and so on. Volume such as the thumb.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        (mA)

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        (mL/min)

                        Weight

                        (g)

                        Pump Size

                        Installation instructions

                        Detailed Structure of the show

                        reference Appearance

                        GminiPB-1

                        3.5

                        100

                        35

                        -25

                        800

                        28

                        162441

                        >>here

                        GminiPB-2

                        3.5

                        100

                        35

                        -20

                        300

                        28

                        162441

                        >>here

                        Ibid

                        GMPA Series of micro-Pump  the pump size is small, current, power consumption, low noise, stable and reliable, with mounting holes for the lithium battery-powered instrument for the pursuit of high-quality user ,With special needs can be put on a positive pressure above 0.1mpa Suction pump for pocket analyzer, gas sampler, medical instrument, beauty instrument and so on.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        (mA)

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        (L/min)

                        Weight

                        (g)

                        Pump Size

                        Installation instructions

                        Structure of the show

                        reference Figure

                        GMPA-1

                        1.5-5

                        test:4V

                        40-100

                        50

                        20-30

                        0.3-1.5

                        35

                        402336

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GMPA-2

                        2.0-5

                        test:4V

                        30-100

                        50

                        30-40

                        0.5-2.0

                        35

                        402336

                        Ibid

                        Ibid

                        GMPA-3

                        3-6

                        40-70

                        50

                        20-30

                        0.5-1.5

                        35

                        402336

                        Ibid

                        Ibid

                        GMPA-4

                        3-6

                        50-90

                        50

                        30-40

                        0.5-1.8

                        35

                        402336

                        Ibid

                        Ibid

                        GMPC Series of micro-pump   the pump size is small, low noise, small power consumption,stable and reliable hand-held devices used to pump suction. particularly suitable for demanding vacuum environments. with special needs can be put on a positive pressure above 0.1mpa .suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        (mA)

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        (L/min)

                        Weight

                        (g)

                        Pump Size

                        Installation instructions

                        Structure of the show

                        reference Figure

                        GMPC-1/2/3

                        6/9/12

                        <200/120/90

                        >100

                        50-65

                        2.5-3

                        45

                        502231

                        Structure>>here

                        flow-load diagram

                        voltage-flow chart

                        GMPC-4/5/6

                        6/9/12

                        <150/110/80

                        >80

                        50-55

                        2.0-2.5

                        45

                        502231 ibid

                        ibid

                        GMPD Series of micro-pumpsuction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump with special needs can be put on a positive pressure above 0.1mpa .

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        (mA)

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        (L/min)

                        Weight

                        (g)

                        Pump Size

                        Installation instructions

                        Structure of the show

                        reference Figure

                        GMPD-1/2/3

                        6/12/24

                        <230/130/80

                        60-100

                        60

                        3-8

                        82

                        3544.556.5

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GMPD-4/5/6

                        6/12/24

                        <200/100/60

                        60-100

                        50

                        3-7

                        82

                        3544.556.5 ibid

                        ibid

                        Custom products 6,9,12,24 volts, flow 2L, 3l, 4l can be customized, there are 20 models

                        GMPE Series of micro-pump To provide a special and long life motor, flow rate no less, suction pumps for pocket gas sampler, medical instrument, beauty instrument, breast pump

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        mA

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GMPE-1/2

                        12/24

                        <180/90

                        60

                        50-55

                        3-6

                        149

                        33543.572

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GMPE-3/4/-

                        12/24 -20-40 Custom 3L4L5L 149 3543.572

                        Note: The custom products 2L, 3L, 4L can be customized, a total of 10 variety

                        GMPF Series of micro-pump   A single-channel pump, flow is very stable, suitable for a variety of gas sampling.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GMPF25-1/2

                        12/24 0.6/.3 >100 -70 25 480 8656.5126

                        Structure>>here

                        GMPF15-3/4

                        12/24 0.6/0.3 >60 -50 18 480 8656.5126

                        Structure>>here

                        GMPG Series of micro-pump A new single-channel pump, flow is very stable, suitable for a variety of gas sampling, changes in motor and voltage can produce six varieties.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GMPG-1/2

                        6-12/24

                        <0.450

                        100

                        20-50

                        36

                        620

                        8670126

                        Structure>>here

                        GMPG-3/4

                        6-9/24

                        <0.550

                        100

                        20-50

                        36

                        620

                        8670126

                        ibid

                        GDMPB Series Mini Double Pump        The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPB-1/2

                        6/12

                        <0.25/0.135

                        100

                        series260

                        -45-55

                        series vacum

                         -85

                        single:22

                        dual:2.8

                        55

                        244749

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GDMPB-3/4

                        6/12

                        <0.25/0.135

                        100

                        series260

                        50-65

                        single:2.52

                        dual:3.8

                        55

                        244749

                        ibid

                        GDMPC Series Mini Double Pump   The pump can be due to double-headed pump gas path phase complementary mix to meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit becomes simple, reducing circuit cost, function more flexible.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPC-1/2

                        12/24

                        <0.135/0.08

                        100

                        series260

                        -45-55

                        series vacum

                        -75

                        single

                        22L/min

                        dual

                        2.8L/min

                        75

                        244751

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GDMPC-3/4

                        12/24

                        <0.135/0.08

                        series

                        260

                        -50-65

                        series vacum

                        -80

                        single:2.52

                        dual:3.8

                        5

                        244751

                        ibid

                        GDMPD Series Mini Double Pump  The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit cost, function more flexible.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        mA

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPD-1/2

                        12/24

                        <200

                        /135

                        100

                        -40-50

                        series vacum

                        -75

                        single:72

                        dual:10

                        107

                        354855.5

                        GDMPD-3/4

                        12/24

                        <240

                        /135

                        100

                        -40-60

                        series vacum

                        -80

                        single:82

                        dual:11

                        107

                        354855.5

                        GDMPD-5/6

                        12/24

                        <180

                        /115

                        100

                        -35-45

                        single:52

                        dual:8

                        107

                        354855.5

                        GDMPE Series Mini Double Pump The pump is designed to meet the user requirements of the design flow, high stability, due to double-headed pump gas path can be complementary and mixed phase can meet the requirements of constant-current sample, while a pump can replace the double-beat and sampling pump so that the system control circuit simple, to reduce circuit costs, function more flexible and longer motor life

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        mA

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPE-1/2

                        12/24

                        <180/100

                        100

                        -40-50

                        series vacum

                        -75

                        single:62

                        dual:10

                        175

                        354871.5

                        flow-load diagram

                        voltage-flow chart

                        Structure>>here

                        GDMPF Series Mini Double Pump  Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, micro-organisms, a variety of gas sampling. gas line more stable.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPF(40)-1/2

                        12/24

                        0.80

                        100

                        20-60

                        single:282

                        dual:40

                        618

                        1056.5126

                        voltage-flow chart

                        Structure>>here

                        GDMPF(25)-3/4

                        12/24

                        0.70

                        100

                        20-60

                        single:202,

                        dual:25

                        663

                        1056.5126

                        ibid

                        GDMPG Series Mini Double Pumpuse of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, sampling of the double-headed just need a pump

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GDMPG(50)-1/2

                        6-12/24

                        <1.0

                        60

                        20-50

                        single:352

                        dual:50

                        759

                        11070126

                        Structure>>here

                        GDMPG(35)-3/4

                        6-12/24

                        <1.0

                        -50-60

                        20-50

                        single:252

                        dual:50

                        759

                        11070126

                        Structure>>here

                        GFMPE Series of four-channel Pump Use of rare earth high-grade fully enclosed motor, flow stability, suitable for dust sampling, microbiological sampling, a variety of gas sampling, can be composed of a four-way mixed-constant pump, flow is very stable.

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        A

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        GFMPE-1/2 12/24 <0.67/0.35 -- 60 Four:5-18 375 4564.5124

                        Structure>>here

                        GFMPE-3/4

                        12/24

                        <0.67/0.35.67

                        --

                        45

                        Four:3-15

                        375 4564.5124
                        Other Four:1-10 375 4564.5124

                        HLA-2 Manual vacuum sampler series Test tube-specific, non-electric manual, negative pressure changes with the personal power

                        Name and model

                        Voltage

                        (V)

                        No-load Current

                        mA

                        Pressure

                        (kPa)

                        Vacum

                        (kPa)

                        Intake Flow

                        L/min

                        Weight(g)

                        Pump Size

                        Structure of the show

                        reference Figure

                        HLA-2

                        --

                        50mL and 100mL two tranches.